<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>暗室のすすめ</title>
	<atom:link href="http://www.voxym.com/dark-room/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.voxym.com/dark-room</link>
	<description>::DarkRoom-Maniacs::</description>
	<lastBuildDate>Thu, 16 Nov 2000 13:38:23 +0000</lastBuildDate>
	<language>ja</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.1.4</generator>
		<item>
		<title>Microdol X</title>
		<link>http://www.voxym.com/dark-room/data/processing/microdol-x/</link>
		<comments>http://www.voxym.com/dark-room/data/processing/microdol-x/#comments</comments>
		<pubDate>Thu, 16 Nov 2000 13:38:23 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[8-2.現像時間データ]]></category>

		<guid isPermaLink="false">http://www.voxym.com/dark-room/?p=395</guid>
		<description><![CDATA[すべて単位は「分」です。 コダックのデータは主にナイコール式、１～２リール用のデータ。露出指数（ＥＩ）はコントラストインデックス=0.56 としたときのもの。30秒につき、少なくとも５秒間にタンクを５～７回すばやく１８０°反転させ攪拌。 EI D:W 18°C 20°C 22°C 24°C Tri-X 400 1:0 11 10 9 8 400 1:3 - - 14 13 Plus-X 125 1:0 8 7 6 5 1/2 125 1:3 - - 10 9 1/2 Neopan 400 PREST0 (135) 200 1:0 9 1/2 8 1/2 7 3/4 7 400 1:0 11 1/4 10 ]]></description>
			<content:encoded><![CDATA[<p>すべて単位は「分」です。</p>
<p>コダックのデータは主にナイコール式、１～２リール用のデータ。露出指数（ＥＩ）はコントラストインデックス=0.56 としたときのもの。30秒につき、少なくとも５秒間にタンクを５～７回すばやく１８０°反転させ攪拌。</p>
<table>
<tr>
<th></th>
<th>EI</th>
<th>D:W</th>
<th>18°C</th>
<th>20°C</th>
<th>22°C</th>
<th>24°C</th>
</tr>
<tr>
<td rowspan="2">Tri-X</td>
<td>400</td>
<td>1:0</td>
<td>11</td>
<td>10</td>
<td>9</td>
<td>8</td>
</tr>
<tr>
<td>400</td>
<td>1:3</td>
<td>-</td>
<td>-</td>
<td>14</td>
<td>13</td>
</tr>
<tr>
<td rowspan="2">Plus-X</td>
<td>125</td>
<td>1:0</td>
<td>8</td>
<td>7</td>
<td>6</td>
<td>5 1/2</td>
</tr>
<tr>
<td>125</td>
<td>1:3</td>
<td>-</td>
<td>-</td>
<td>10</td>
<td>9 1/2</td>
</tr>
<tr>
<td rowspan="2">Neopan 400<br />
			PREST0 (135)</td>
<td>200</td>
<td>1:0</td>
<td>9 1/2</td>
<td>8 1/2</td>
<td>7 3/4</td>
<td>7</td>
</tr>
<tr>
<td>400</td>
<td>1:0</td>
<td>11 1/4</td>
<td>10</td>
<td>9</td>
<td>8</td>
</tr>
<tr>
<td rowspan="2">Neopan 1600<br />
			SUPER PREST0</td>
<td>400</td>
<td>1:0</td>
<td>8</td>
<td>6 1/2</td>
<td>5 1/4</td>
<td>-</td>
</tr>
<tr>
<td>800</td>
<td>1:0</td>
<td>10</td>
<td>8 1/4</td>
<td>6 3/4</td>
<td>5 1/2</td>
</tr>
<tr>
<td>Neopn 100 ACROS</td>
<td>100</td>
<td>1:0</td>
<td>13 1/2</td>
<td>11 1/2</td>
<td>9 3/4</td>
<td>8 1/4</td>
</tr>
<tr>
<td>Neopan F</td>
<td>32</td>
<td>1:0</td>
<td>9</td>
<td>8</td>
<td>7</td>
<td>6 1/2</td>
</tr>
<tr>
<td>Agfa APX 400</td>
<td>250</td>
<td>1:0</td>
<td>-</td>
<td>18</td>
<td>-</td>
<td>-</td>
</tr>
<tr>
<td>Agfa APX 100</td>
<td>50</td>
<td>1:0</td>
<td>-</td>
<td>14 1/2</td>
<td>-</td>
<td>-</td>
</tr>
</table>
<p>小型タンク（主に反転させても液漏れの無いもの）を使用した場合のデータ。<br />
大型タンク、又は深タンク（直方体、およびそれに類するもの、フタの無い浴層へ浸けるもの等） の場合は、 表記の現像時間より、５％～１０％処理時間を延ばす必要がある。 詳しくは 各メーカーの公式データシートを参照の事。<br />
＠初期攪拌についての記載は無く、攪拌も秒数より反転回数とその速さに重点が置かれている。 （タンクの上下を挟むように持ち、手首を回転させるように、とある） 結局は参考値として、各自データを獲る事になると思われる。 </p>
<p>フジフィルム 最初の１分は、連続攪拌。のち１分につき５秒の攪拌。<br />
＠コントラストインデックス、γ値に類する表記無し。 </p>
<p>アグファ 実効感度（ISO)はネガのコントラストを標準γ値=0.65とする場合の処理時間。 最初の1分は連続攪拌、後３０秒ごと１回。<br />
＠攪拌方法についての詳しい記載無し。 又、「攪拌方法により結果に違いがでることもあります」とあるので、 これを元に各自データを獲る事をメーカーとしては推奨している、と思われる。</p>
]]></content:encoded>
			<wfw:commentRss>http://www.voxym.com/dark-room/data/processing/microdol-x/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>T-max</title>
		<link>http://www.voxym.com/dark-room/data/processing/t-max/</link>
		<comments>http://www.voxym.com/dark-room/data/processing/t-max/#comments</comments>
		<pubDate>Thu, 16 Nov 2000 13:36:02 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[8-2.現像時間データ]]></category>

		<guid isPermaLink="false">http://www.voxym.com/dark-room/?p=392</guid>
		<description><![CDATA[すべて単位は「分」です。 小型タンク（主に反転させても液漏れの無いもの）を使用した場合のデータ。 大型タンク、又は深タンク（直方体、およびそれに類するもの、フタの無い浴層へ浸けるもの等） の場合は、 表記の現像時間より、５％～１０％処理時間を延ばす必要がある。 詳しくは 各メーカーの公式データシートを参照の事。 EI D:W 18°C 20°C 22°C 24°C T-Max 100 *1-b 100-200 1:4 - 8 7 6 1/2 100-200 1:7 - - - 10 100-200 1:9 - - - 14 T-Max 400 *1-b 400-800 1:4 - 7 6 1/2 6 400-800 1:7 - - - 10 400-800 1:9 - - ]]></description>
			<content:encoded><![CDATA[<p>すべて単位は「分」です。</p>
<p>小型タンク（主に反転させても液漏れの無いもの）を使用した場合のデータ。<br />
大型タンク、又は深タンク（直方体、およびそれに類するもの、フタの無い浴層へ浸けるもの等）<br />
の場合は、 表記の現像時間より、５％～１０％処理時間を延ばす必要がある。<br />
詳しくは 各メーカーの公式データシートを参照の事。</p>
<table>
<tbody>
<tr>
<th></th>
<th>EI</th>
<th>D:W</th>
<th>18°C</th>
<th>20°C</th>
<th>22°C</th>
<th>24°C</th>
</tr>
<tr>
<td rowspan="3">T-Max 100</p>
<p><a href="#note1-b">*1-b</a></td>
<td>100-200</td>
<td>1:4</td>
<td>-</td>
<td>8</td>
<td>7</td>
<td>6 1/2</td>
</tr>
<tr>
<td>100-200</td>
<td>1:7</td>
<td>-</td>
<td>-</td>
<td>-</td>
<td>10</td>
</tr>
<tr>
<td>100-200</td>
<td>1:9</td>
<td>-</td>
<td>-</td>
<td>-</td>
<td>14</td>
</tr>
<tr>
<td rowspan="3">T-Max 400</p>
<p><a href="#note1-b">*1-b</a></td>
<td>400-800</td>
<td>1:4</td>
<td>-</td>
<td>7</td>
<td>6 1/2</td>
<td>6</td>
</tr>
<tr>
<td>400-800</td>
<td>1:7</td>
<td>-</td>
<td>-</td>
<td>-</td>
<td>10</td>
</tr>
<tr>
<td>400-800</td>
<td>1:9</td>
<td>-</td>
<td>-</td>
<td>-</td>
<td>15</td>
</tr>
<tr>
<td rowspan="3">Tri-X</p>
<p><a href="#note">*1</a></td>
<td>400</td>
<td>1:4</td>
<td>7</td>
<td>6</td>
<td>5 1/2</td>
<td>5 1/2</td>
</tr>
<tr>
<td>1600</td>
<td>1:4</td>
<td>11 1/2</td>
<td>10</td>
<td>9</td>
<td>8 1/2</td>
</tr>
<tr>
<td>3200</td>
<td>1:4</td>
<td>-</td>
<td>-</td>
<td>-</td>
<td>11</td>
</tr>
<tr>
<td rowspan="2">Plus-X</p>
<p><a href="#note">*1</a></td>
<td>125</td>
<td>1:4</td>
<td>6 1/2</td>
<td>5 1/2</td>
<td>5</td>
<td>5</td>
</tr>
<tr>
<td>500</td>
<td>1:4</td>
<td>-</td>
<td>-</td>
<td>-</td>
<td>9</td>
</tr>
<tr>
<td rowspan="3">Neopan 400 Presto</p>
<p>(135)</p>
<p><a href="#note2">*2</a></td>
<td>400</td>
<td>1:4</td>
<td>7</td>
<td>6</td>
<td>5</td>
<td>-</td>
</tr>
<tr>
<td>800</td>
<td>1:4</td>
<td>8 3/4</td>
<td>7 1/2</td>
<td>6 1/2</td>
<td>5 1/4</td>
</tr>
<tr>
<td>1600</td>
<td>1:4</td>
<td>11 1/4</td>
<td>10</td>
<td>9</td>
<td>8</td>
</tr>
<tr>
<td rowspan="2">Neopan 1600 Super-</p>
<p>Presto (135)<a href="#note2">*2</a></td>
<td>1600</td>
<td>1:4</td>
<td>5 1/2</td>
<td>-</td>
<td>-</td>
<td>-</td>
</tr>
<tr>
<td>3200</td>
<td>1:4</td>
<td>12</td>
<td>10</td>
<td>8 1/2</td>
<td>7 1/2</td>
</tr>
<tr>
<td rowspan="2">Neopan 100 Acros<a href="#note2">*2</a></td>
<td>100</td>
<td>1:4</td>
<td>6 1/2</td>
<td>5 1/2</td>
<td>-</td>
<td>-</td>
</tr>
<tr>
<td>200</td>
<td>1:4</td>
<td>9 1/2</td>
<td>8</td>
<td>6 1/2</td>
<td>5 1/2</td>
</tr>
<tr>
<td>Agfa APX400 <a href="#note3">*3</a></td>
<td>500</td>
<td>1:4</td>
<td>-</td>
<td>9</td>
<td>-</td>
<td>-</td>
</tr>
<tr>
<td>Agfa APX100 <a href="#note3">*3</a></td>
<td>160</td>
<td>1:4</td>
<td>-</td>
<td>6 1/2</td>
<td>-</td>
<td>-</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th></th>
<th>EI</th>
<th>D:W</th>
<th>18°C</th>
<th>20°C</th>
<th>22°C</th>
<th>24°C</th>
<th>29°C</th>
</tr>
<tr>
<td rowspan="4">T-Max</p>
<p>3200</p>
<p><a href="#note1-b">*1-b</a></td>
<td>3200</td>
<td>1:4</td>
<td>-</td>
<td>11 1/2</td>
<td>10 1/2</td>
<td>9 1/2</td>
<td>6 1/2</td>
</tr>
<tr>
<td>6400</td>
<td>1:4</td>
<td>-</td>
<td>14</td>
<td>12</td>
<td>11</td>
<td>8</td>
</tr>
<tr>
<td>12500</p>
<p><a href="#note1-c">*1-c</a></td>
<td>1:4</td>
<td>-</td>
<td>16</td>
<td>14 1/2</td>
<td>10 1/2</td>
<td>9</td>
</tr>
<tr>
<td>25000</p>
<p><a href="#note1-c">*1-c</a></td>
<td>1:4</td>
<td>-</td>
<td>-</td>
<td>16</td>
<td>14</td>
<td>10</td>
</tr>
</tbody>
</table>
<p>*1&#8212;コダック TriX &amp;Plus-X 主にナイコール式、１～２リール用のデータ。<br />
露出指数（ＥＩ）はコントラストインデックス=0.56 としたときのもの。<br />
30秒につき、少なくとも５秒間にタンクを５～７回すばやく１８０°反転させ攪拌。</p>
<p>＠初期攪拌についての記載は無く、攪拌も秒数より反転回数とその速さに重点が置かれている。<br />
（タンクの上下を挟むように持ち、手首を回転させるように、とある）<br />
結局は参考値として、各自データを獲る事になると思われる。</p>
<p>*1-b&#8212;コダック T-Max 主にナイコール式、１～２リール用のデータとされる。<br />
30秒につき、少なくとも５秒間にタンクを５～７回すばやく１８０°反転させ攪拌。<br />
コントラストについては、撮影状況によりテストして、望ましい結果を得るようテスト。<br />
（同じ処理条件下で 露出指数が幅があるのはこれが考慮にはいっているものと思われる）<br />
＠初期攪拌についての記載は無く、攪拌も秒数より反転回数とその速さに重点が置かれている。<br />
（タンクの上下を挟むように持ち、手首を回転させるように、とある）<br />
結局は参考値として、各自データを獲る事になると思われる。</p>
<p>*1-c&#8212;コダック T-Max３２００における、高感度撮影の増感処理について<br />
撮影状況によりテストして、望ましい結果を得るようテストする事。</p>
<p>*2&#8212;フジフィルム 最初の１分は、連続攪拌。のち１分につき５秒の攪拌。<br />
＠コントラストインデックス、γ値に類する表記無し。</p>
<p>*3&#8212;アグファ 実効感度（ISO)はネガのコントラストを標準γ値=0.65とする場合の処理時間。<br />
最初の1分は連続攪拌、後３０秒ごと１回。 ＠攪拌方法についての詳しい記載無し。<br />
又、「攪拌方法により結果に違いがでることもあります」とあるので、<br />
これを元に各自データを獲る事をメーカーとしては推奨している、と思われる。</p>
<p><a href="http://hb.afl.rakuten.co.jp/hgc/0de25bf0.9bbb6238.0de25bf1.3160d7a3/?pc=http%3a%2f%2fitem.rakuten.co.jp%2finaphot%2ffilm_k_tmax400-36%2f%3fscid%3daf_ich_link_img&#038;m=http%3a%2f%2fm.rakuten.co.jp%2finaphot%2fi%2f10001229%2f" target="_blank"><img src ="http://hbb.afl.rakuten.co.jp/hgb/?pc=http%3a%2f%2fthumbnail.image.rakuten.co.jp%2f%400_mall%2finaphot%2fcabinet%2f01031186%2fimg61621397.jpg%3f_ex%3d240x240&#038;m=http%3a%2f%2fthumbnail.image.rakuten.co.jp%2f%400_mall%2finaphot%2fcabinet%2f01031186%2fimg61621397.jpg%3f_ex%3d80x80" border="0"></a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.voxym.com/dark-room/data/processing/t-max/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>D-76</title>
		<link>http://www.voxym.com/dark-room/data/processing/d-76-2/</link>
		<comments>http://www.voxym.com/dark-room/data/processing/d-76-2/#comments</comments>
		<pubDate>Thu, 16 Nov 2000 13:31:54 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[8-2.現像時間データ]]></category>

		<guid isPermaLink="false">http://www.voxym.com/dark-room/?p=387</guid>
		<description><![CDATA[すべて単位は「分」です。 30秒につき、少なくとも５秒間にタンクを５～７回すばやく１８０°反転させ攪拌する。 コダックに由ればD-76は希釈して保存は不能と指示されている。 小型タンク（主に反転させても液漏れの無いもの）を使用した場合のデータ。 大型タンク、又は深タンク（直方体、およびそれに類するもの、フタの無い 浴層へ浸けるもの等）の場合は、 表記の現像時間より、５％～１０％処理 時間を延ばす必要がある。 厳密には 各メーカーの公式データシートを参照の事。 EI D:W 18°C 20°C 22°C 24°C Tri-X 400 1:0 9 8 6 1/2 5 1/2 1600 1:0 16 13 11 10 400 1:1 11 10 9 8 Prus-X 125 1:0 6 1/2 5 1/2 - - 125 1:1 8 7 6 5 VERI CHROME Pan ]]></description>
			<content:encoded><![CDATA[<p>すべて単位は「分」です。</p>
<ul>
<li>30秒につき、少なくとも５秒間にタンクを５～７回すばやく１８０°反転させ攪拌する。</li>
<li>コダックに由ればD-76は希釈して保存は不能と指示されている。 </li>
<li>小型タンク（主に反転させても液漏れの無いもの）を使用した場合のデータ。 </li>
<li>大型タンク、又は深タンク（直方体、およびそれに類するもの、フタの無い 浴層へ浸けるもの等）の場合は、 表記の現像時間より、５％～１０％処理 時間を延ばす必要がある。</li>
<li> 厳密には 各メーカーの公式データシートを参照の事。 </li>
</ul>
<table>
<tr>
<th></th>
<th>EI</th>
<th>D:W</th>
<th>18°C</th>
<th>20°C</th>
<th>22°C</th>
<th>24°C</th>
</tr>
<tr>
<td rowspan="3">Tri-X</td>
<td>400</td>
<td>1:0</td>
<td>9</td>
<td>8</td>
<td>6 1/2</td>
<td>5 1/2</td>
</tr>
<tr>
<td>1600</td>
<td>1:0</td>
<td>16</td>
<td>13</td>
<td>11</td>
<td>10</td>
</tr>
<tr>
<td>400</td>
<td>1:1</td>
<td>11</td>
<td>10</td>
<td>9</td>
<td>8</td>
</tr>
<tr>
<td rowspan="2">Prus-X</td>
<td>125</td>
<td>1:0</td>
<td>6 1/2</td>
<td>5 1/2</td>
<td>-</td>
<td>-</td>
</tr>
<tr>
<td>125</td>
<td>1:1</td>
<td>8</td>
<td>7</td>
<td>6</td>
<td>5</td>
</tr>
<tr>
<td rowspan="2">VERI CHROME Pan 120</td>
<td>100</td>
<td>1:0</td>
<td>8</td>
<td>7</td>
<td>5</td>
<td>-</td>
</tr>
<tr>
<td>100</td>
<td>1:1</td>
<td>11</td>
<td>9</td>
<td>7</td>
<td>6</td>
</tr>
<tr>
<td>High Speed Infrared</td>
<td>&#8211;</td>
<td>1:0</td>
<td>9 1/2</td>
<td>8 1/2</td>
<td>7</td>
<td>6</td>
</tr>
<tr>
<td rowspan="4">Neopan<br />
			400<br />
			PRESTO<br />
			(135)</td>
<td>400</td>
<td>1:0</td>
<td>9 1/4</td>
<td>7 1/2</td>
<td>6 1/4</td>
<td>5</td>
</tr>
<tr>
<td>800</td>
<td>1:0</td>
<td>10 3/4</td>
<td>8 3/4</td>
<td>7 1/4</td>
<td>5 3/4</td>
</tr>
<tr>
<td>1600</td>
<td>1:0</td>
<td>16 1/2</td>
<td>13 1/2</td>
<td>11</td>
<td>9 1/4</td>
</tr>
<tr>
<td>400</td>
<td>1:1</td>
<td>10 3/4</td>
<td>9 1/2</td>
<td>8 1/2</td>
<td>7 1/2</td>
</tr>
<tr>
<td rowspan="4">Neopan<br />
			400<br />
			PRESTO<br />
			(120)</td>
<td>250</td>
<td>1:0</td>
<td>7 3/4</td>
<td>6 1/2</td>
<td>5 1/2</td>
<td>-</td>
</tr>
<tr>
<td>400</td>
<td>1:0</td>
<td>9 1/4</td>
<td>7 1/2</td>
<td>6 1/4</td>
<td>5 1/4</td>
</tr>
<tr>
<td>800</td>
<td>1:0</td>
<td>11 1/2</td>
<td>9 1/2</td>
<td>7 3/4</td>
<td>6 1/2</td>
</tr>
<tr>
<td>400</td>
<td>1:1</td>
<td>11 1/2</td>
<td>9 3/4</td>
<td>8 1/4</td>
<td>7</td>
</tr>
<tr>
<td rowspan="6">Neopan<br />
			1600<br />
			Super<br />
			PRESTO</td>
<td>800</td>
<td>1:0</td>
<td>6</td>
<td>5</td>
<td>-</td>
<td>-</td>
</tr>
<tr>
<td>1600</td>
<td>1:0</td>
<td>9</td>
<td>7 1/2</td>
<td>6</td>
<td>5</td>
</tr>
<tr>
<td>3200</td>
<td>1:0</td>
<td>-</td>
<td>15</td>
<td>12</td>
<td>10</td>
</tr>
<tr>
<td>400</td>
<td>1:1</td>
<td>6 1/2</td>
<td>5 1/2</td>
<td>-</td>
<td>-</td>
</tr>
<tr>
<td>800</td>
<td>1:1</td>
<td>8</td>
<td>7</td>
<td>6</td>
<td>5</td>
</tr>
<tr>
<td>1600</td>
<td>1:1</td>
<td>11</td>
<td>9</td>
<td>7 1/2</td>
<td>6 1/2</td>
</tr>
<tr>
<td rowspan="3">Neopan<br />
			100<br />
			ACROS</td>
<td>100</td>
<td>1:0</td>
<td>8 1/2</td>
<td>7 1/4</td>
<td>6 1/4</td>
<td>5 1/4</td>
</tr>
<tr>
<td>200</td>
<td>1:0</td>
<td>12</td>
<td>10</td>
<td>8 1/2</td>
<td>7</td>
</tr>
<tr>
<td>100</td>
<td>1:1</td>
<td>13</td>
<td>10 1/2</td>
<td>8 3/4</td>
<td>7 1/4</td>
</tr>
<tr>
<td rowspan="4">Neopan<br />
			F</td>
<td>32</td>
<td>1:0</td>
<td>7 1/4</td>
<td>6</td>
<td>5</td>
<td>-</td>
</tr>
<tr>
<td>40</td>
<td>1:0</td>
<td>7 3/4</td>
<td>6 1/2</td>
<td>5 1/2</td>
<td>-</td>
</tr>
<tr>
<td>32</td>
<td>1:1</td>
<td>9</td>
<td>8</td>
<td>7</td>
<td>6 1/4</td>
</tr>
<tr>
<td>40</td>
<td>1:1</td>
<td>9 3/4</td>
<td>8 1/2</td>
<td>7 1/2</td>
<td>6 1/2</td>
</tr>
<tr>
<td>Agfa APX400</td>
<td>400</td>
<td>1:0</td>
<td>-</td>
<td>10</td>
<td>-</td>
<td>-</td>
</tr>
<tr>
<td>Agfa APX100</td>
<td>80</td>
<td>1:0</td>
<td>-</td>
<td>7</td>
<td>-</td>
<td>-</td>
</tr>
<tr>
<th></th>
<th>EI</th>
<th>D:W</th>
<th>18°C</th>
<th>20°C</th>
<th>22°C</th>
<th>24°C</th>
</tr>
</table>
<p>コダック＠初期攪拌についての記載は無く、攪拌も秒数より反転回数とその速さに重点が置かれている。タンクの上下を挟むように持ち、手首を回転させるように、とある－－－つまり片手で上下が掴める＝１～２本用のナイコール式タンクを前提としたデータであることに注意する。結局は参考値として、各自データを獲る事になると思われる</p>
<p>露出指数（ＥＩ）はコントラストインデックス=0.56 (ベリクロームは.0.6,)としたときのもの。High Speed InfraredについてはCI=0,70 としたもののデータ<br />
この時のEI及びISOについては 赤外フィルムの特性上明確に示せない<br />
（露出計の指示は基本的に役立たない,・これは、赤外線の量に左右されるものであり、さらに使用するフィルターのシャープカットの度合い、撮影対象の赤外線反射量、及び吸収量によりいかようにも変化するものだからである。）<br />
コダックによれば、段階露光をするよう薦めている。</p>
<p>フジフィルム 最初の１分は、連続攪拌。のち１分につき５秒の攪拌。<br />
＠コントラストインデックス、γ値に類する表記無し。</p>
<p>アグファ 実効感度（ISO)はネガのコントラストを標準γ値=0.65とする場合の処理時間。最初の1分は連続攪拌、後３０秒ごと１回。<br />
＠攪拌方法についての詳しい記載無し。又、「攪拌方法により結果に違いがでることもあります」とあるので、これを元に各自データを獲る事をメーカーとしては推奨している、と思われる。</p>
]]></content:encoded>
			<wfw:commentRss>http://www.voxym.com/dark-room/data/processing/d-76-2/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>現像時間</title>
		<link>http://www.voxym.com/dark-room/data/processing/info-2/</link>
		<comments>http://www.voxym.com/dark-room/data/processing/info-2/#comments</comments>
		<pubDate>Thu, 16 Nov 2000 13:30:48 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[8-2.現像時間データ]]></category>

		<guid isPermaLink="false">http://www.voxym.com/dark-room/?p=385</guid>
		<description><![CDATA[データはメーカーの公式発表による、フィルム、及び現像液薬品に付随した使用説明書、又は、 写真用品店 店頭に置かれているパンフレット、その他等を基に構成しています。そのため、攪拌方法等はそのデータを発表したメーカーにより異なっています。 警告誤植等の可能性が皆無とも言いきれません。あくまで、参考値として参照して下さい。当データを基に処理をした上で何らかの事故が生じたとしても、当方は一切関知しません。処理に当たってはあくまで自己責任において行って下さい。攪拌方法その他詳しくは末尾の詳細についても参照して下さい。]]></description>
			<content:encoded><![CDATA[<p>データはメーカーの公式発表による、フィルム、及び現像液薬品に付随した使用説明書、又は、 写真用品店 店頭に置かれているパンフレット、その他等を基に構成しています。そのため、攪拌方法等はそのデータを発表したメーカーにより異なっています。</p>
<p>警告誤植等の可能性が皆無とも言いきれません。あくまで、参考値として参照して下さい。当データを基に処理をした上で何らかの事故が生じたとしても、当方は一切関知しません。処理に当たってはあくまで自己責任において行って下さい。攪拌方法その他詳しくは末尾の詳細についても参照して下さい。</p>
]]></content:encoded>
			<wfw:commentRss>http://www.voxym.com/dark-room/data/processing/info-2/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>SD-4</title>
		<link>http://www.voxym.com/dark-room/data/developer/sd-4/</link>
		<comments>http://www.voxym.com/dark-room/data/developer/sd-4/#comments</comments>
		<pubDate>Thu, 16 Nov 2000 13:25:21 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[8-1.現像液の処方箋]]></category>

		<guid isPermaLink="false">http://www.voxym.com/dark-room/?p=381</guid>
		<description><![CDATA[映画ネガ用。スチール用には、露光不足ネガの救済（あるいは、増感用）軟調現像液として。  ２浴式（Ａ液で処理したのち、B液で処理） 各処理液で、４分～５分 Ａ液処理後、水洗せずにB液処理に入る事 Ａ液 Ｂ液 総量1000ml中 総量1000ml中 メトール 5g &#8211; 無水亜硫酸ナトリウム 100g 100g ハイドロキノン 2g &#8211; 亜硫酸水素ナトリウム 5g &#8211; 無水炭酸ナトリウム &#8211; 10g 砂糖 100g &#8211; 臭化カリウム &#8211; 0.5g ヨウ化カリウム0,1%液 &#8211; 10ml]]></description>
			<content:encoded><![CDATA[<p>映画ネガ用。スチール用には、露光不足ネガの救済（あるいは、増感用）軟調現像液として。 <br />
２浴式（Ａ液で処理したのち、B液で処理）<br />
各処理液で、４分～５分 Ａ液処理後、水洗せずにB液処理に入る事</p>
<table>
<tr>
<th></th>
<th>Ａ液</th>
<th>Ｂ液</th>
</tr>
<tr>
<td></td>
<td>総量1000ml中</td>
<td>総量1000ml中</td>
</tr>
<tr>
<td>メトール</td>
<td>5g</td>
<td>&#8211;</td>
</tr>
<tr>
<td>無水亜硫酸ナトリウム</td>
<td>100g</td>
<td>100g</td>
</tr>
<tr>
<td>ハイドロキノン</td>
<td>2g</td>
<td>&#8211;</td>
</tr>
<tr>
<td>亜硫酸水素ナトリウム</td>
<td>5g</td>
<td>&#8211;</td>
</tr>
<tr>
<td>無水炭酸ナトリウム</td>
<td>&#8211;</td>
<td>10g</td>
</tr>
<tr>
<td>砂糖</td>
<td>100g</td>
<td>&#8211;</td>
</tr>
<tr>
<td>臭化カリウム</td>
<td>&#8211;</td>
<td>0.5g</td>
</tr>
<tr>
<td>ヨウ化カリウム0,1%液</td>
<td>&#8211;</td>
<td>10ml</td>
</tr>
</table>
]]></content:encoded>
			<wfw:commentRss>http://www.voxym.com/dark-room/data/developer/sd-4/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>TEA-14</title>
		<link>http://www.voxym.com/dark-room/data/developer/tea-14/</link>
		<comments>http://www.voxym.com/dark-room/data/developer/tea-14/#comments</comments>
		<pubDate>Thu, 16 Nov 2000 13:24:48 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[8-1.現像液の処方箋]]></category>

		<guid isPermaLink="false">http://www.voxym.com/dark-room/?p=378</guid>
		<description><![CDATA[高感度軟調 ＰＱ 現像液 （増感現像液） D-76より、現像時間は長いが、より軟調、且つ高感度(暗部描写に優れる）となる。 Tri-X 20℃ 10分～15分で、軟調、 且つD-76に比して３～５倍の感度が得られる。 水 800ml 無水亜硫酸ナトリウム 4g 臭化カリウム 1g ポリエチレングリコール6000 2g トリエタノールアミン(濃厚） 20ml フェニドン 1.07g ハイドロキノン 0.5g 水を加えて総量 1000ml]]></description>
			<content:encoded><![CDATA[<p>高感度軟調 ＰＱ 現像液 （増感現像液） D-76より、現像時間は長いが、より軟調、且つ高感度(暗部描写に優れる）となる。<br />
Tri-X 20℃ 10分～15分で、軟調、 且つD-76に比して３～５倍の感度が得られる。</p>
<table>
<tr>
<td>水</td>
<td>800ml</td>
</tr>
<tr>
<td>無水亜硫酸ナトリウム</td>
<td>4g</td>
</tr>
<tr>
<td>臭化カリウム</td>
<td>1g</td>
</tr>
<tr>
<td>ポリエチレングリコール6000</td>
<td>2g</td>
</tr>
<tr>
<td>トリエタノールアミン(濃厚）</td>
<td>20ml</td>
</tr>
<tr>
<td>フェニドン</td>
<td>1.07g</td>
</tr>
<tr>
<td>ハイドロキノン</td>
<td>0.5g</td>
</tr>
<tr>
<td>水を加えて総量</td>
<td>1000ml</td>
</tr>
</table>
]]></content:encoded>
			<wfw:commentRss>http://www.voxym.com/dark-room/data/developer/tea-14/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>POTA</title>
		<link>http://www.voxym.com/dark-room/data/developer/pota/</link>
		<comments>http://www.voxym.com/dark-room/data/developer/pota/#comments</comments>
		<pubDate>Thu, 16 Nov 2000 13:24:18 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[8-1.現像液の処方箋]]></category>

		<guid isPermaLink="false">http://www.voxym.com/dark-room/?p=375</guid>
		<description><![CDATA[超軟調現像液 硬調印画紙にプリントする場合、光源を持つような極めて高いコントラストの被写体を撮影する場合、また、コピーフィルムで一般撮影する場合等に良好なネガが得られる。  *)軟調に過ぎる場合ハイドロキノンを添加。 水（40℃） 750ml 無水亜硫酸ナトリウム 30g ハイドロキノン* 0g~1g* フェニドン 1.5g 水を加えて総量 1000ml]]></description>
			<content:encoded><![CDATA[<p>超軟調現像液 硬調印画紙にプリントする場合、光源を持つような極めて高いコントラストの被写体を撮影する場合、また、コピーフィルムで一般撮影する場合等に良好なネガが得られる。 <br />
*)軟調に過ぎる場合ハイドロキノンを添加。</p>
<table>
<tr>
<td>水（40℃）</td>
<td>750ml</td>
</tr>
<tr>
<td>無水亜硫酸ナトリウム</td>
<td>30g</td>
</tr>
<tr>
<td>ハイドロキノン*</td>
<td>0g~1g*</td>
</tr>
<tr>
<td>フェニドン</td>
<td>1.5g</td>
</tr>
<tr>
<td>水を加えて総量</td>
<td>1000ml</td>
</tr>
</table>
]]></content:encoded>
			<wfw:commentRss>http://www.voxym.com/dark-room/data/developer/pota/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>FX-1</title>
		<link>http://www.voxym.com/dark-room/data/developer/fx-1/</link>
		<comments>http://www.voxym.com/dark-room/data/developer/fx-1/#comments</comments>
		<pubDate>Thu, 16 Nov 2000 13:23:38 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[8-1.現像液の処方箋]]></category>

		<guid isPermaLink="false">http://www.voxym.com/dark-room/?p=372</guid>
		<description><![CDATA[高鮮鋭度処方。エッジ効果が極めて高い。微粒子効果は期待できない。  現像液に、微粒子効果が期待できないため、微粒子硬調フィルムに向いているとされる。 *)撮影時の露出は厳密に。さらに、フレア等ないようにする。原液で使用し、また反復使用は出来ない。 水（三分煮沸後40℃） 750ml メトール 0.5g 無水亜硫酸ナトリウム 5g 無水炭酸ナトリウム 2.5g ヨウ化カリウム0.001%溶液 5ml 水を加えて総量 1000ml]]></description>
			<content:encoded><![CDATA[<p>高鮮鋭度処方。エッジ効果が極めて高い。微粒子効果は期待できない。 <br />
現像液に、微粒子効果が期待できないため、微粒子硬調フィルムに向いているとされる。<br />
*)撮影時の露出は厳密に。さらに、フレア等ないようにする。原液で使用し、また反復使用は出来ない。</p>
<table>
<tr>
<td>水（三分煮沸後40℃）</td>
<td>750ml</td>
</tr>
<tr>
<td>メトール</td>
<td>0.5g</td>
</tr>
<tr>
<td>無水亜硫酸ナトリウム</td>
<td>5g</td>
</tr>
<tr>
<td>無水炭酸ナトリウム</td>
<td>2.5g</td>
</tr>
<tr>
<td>ヨウ化カリウム0.001%溶液</td>
<td>5ml</td>
</tr>
<tr>
<td>水を加えて総量</td>
<td>1000ml</td>
</tr>
</table>
]]></content:encoded>
			<wfw:commentRss>http://www.voxym.com/dark-room/data/developer/fx-1/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>ボイトラー氏高鮮鋭度処方</title>
		<link>http://www.voxym.com/dark-room/data/developer/beutler/</link>
		<comments>http://www.voxym.com/dark-room/data/developer/beutler/#comments</comments>
		<pubDate>Thu, 16 Nov 2000 13:22:14 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[8-1.現像液の処方箋]]></category>

		<guid isPermaLink="false">http://www.voxym.com/dark-room/?p=370</guid>
		<description><![CDATA[高鮮鋭度処方。エッジ効果が高く、微粒子効果は期待できない。 Ａ ： Ｂ ： 水 ＝ １：１：１０で使用する。使用液は一回限り。 現像液に、微粒子効果が期待できないため、微粒子硬調フィルム に向いているとされる。 Ａ液 Ｂ液 水（50℃） 750ml 750ml メトール 10g &#8211; 無水亜硫酸ナトリウム 50g &#8211; 無水炭酸ナトリウム &#8211; 50g 水を加えて総量 1000ml 1000ml]]></description>
			<content:encoded><![CDATA[<p>高鮮鋭度処方。エッジ効果が高く、微粒子効果は期待できない。<br />
Ａ ： Ｂ ： 水 ＝ １：１：１０で使用する。使用液は一回限り。 現像液に、微粒子効果が期待できないため、微粒子硬調フィルム に向いているとされる。</p>
<table>
<tr>
<th></th>
<th>Ａ液</th>
<th>Ｂ液</th>
</tr>
<tr>
<td>水（50℃）</td>
<td>750ml</td>
<td>750ml</td>
</tr>
<tr>
<td>メトール</td>
<td>10g</td>
<td>&#8211;</td>
</tr>
<tr>
<td>無水亜硫酸ナトリウム</td>
<td>50g</td>
<td>&#8211;</td>
</tr>
<tr>
<td>無水炭酸ナトリウム</td>
<td>&#8211;</td>
<td>50g</td>
</tr>
<tr>
<td>水を加えて総量</td>
<td>1000ml</td>
<td>1000ml</td>
</tr>
</table>
]]></content:encoded>
			<wfw:commentRss>http://www.voxym.com/dark-room/data/developer/beutler/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>MICRODOL type</title>
		<link>http://www.voxym.com/dark-room/data/developer/microdol-type/</link>
		<comments>http://www.voxym.com/dark-room/data/developer/microdol-type/#comments</comments>
		<pubDate>Thu, 16 Nov 2000 13:21:05 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[8-1.現像液の処方箋]]></category>

		<guid isPermaLink="false">http://www.voxym.com/dark-room/?p=367</guid>
		<description><![CDATA[一般ネガ用。原液で極微粒子、希釈して超微粒子。メトール単液現像液 水（50℃） 750ml メトール 5g 無水亜硫酸ナトリウム 100g 食塩 30g 水を加えて総量 1000ml]]></description>
			<content:encoded><![CDATA[<p>一般ネガ用。原液で極微粒子、希釈して超微粒子。メトール単液現像液</p>
<table>
<tr>
<td>水（50℃）</td>
<td align="right">750ml</td>
</tr>
<tr>
<td>メトール</td>
<td align="right">5g</td>
</tr>
<tr>
<td>無水亜硫酸ナトリウム</td>
<td align="right">100g</td>
</tr>
<tr>
<td>食塩</td>
<td align="right">30g</td>
</tr>
<tr>
<td>水を加えて総量</td>
<td align="right">1000ml</td>
</tr>
</table>
]]></content:encoded>
			<wfw:commentRss>http://www.voxym.com/dark-room/data/developer/microdol-type/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>

